The INWELT PT45 45A Air-Cooled Plasma Cutting Torch is a handheld, non-high-frequency (Non-HF) torch intended for compatible plasma cutting systems. It has a 60% duty cycle, operates with air or nitrogen at 4.5–5.0 bar, and requires approximately 120–130 L/min gas flow. The standard cable length is 4 m, with 55 seconds of post-flow recommended to support torch cooling after cutting. For safe selection, buyers should confirm arc-starting method, rear connector, control wiring, power-source compatibility, and consumables. INWELT welcomes wholesale, distributor, and OEM inquiries for PT45 torch assemblies.
PT45
INWELT
45Amp
60%
Air/N2
4.5-5.0 Bar
120-130LPM
Without HF
55 Sec.Recommeded
4 M
| Availability: | |
|---|---|
| Quantity: | |
INWELT PT45 Plasma Cutting Torch | 45A | Non-HF Starting | Air/N₂ | 4M Cable | 60% Duty Cycle
The INWELT PT45 45A Air-Cooled Plasma Cutting Torch is a handheld, non-high-frequency (Non-HF) plasma cutting torch designed for compatible 45A-class plasma cutting systems.
Rated at 45A with a 60% duty cycle, the PT45 supports air or nitrogen (N₂) operation, a specified gas pressure of 4.5–5.0 bar, and a gas flow of 120–130 L/min. The standard torch cable length is 4 meters, with 55 seconds of post-flow recommended to support torch cooling after cutting.
The PT45 is intended for manual cutting of electrically conductive metals, including mild steel, stainless steel, and aluminum, when connected to a compatible plasma power source.
INWELT welcomes wholesale, distributor, and OEM inquiries for complete PT45 torch assemblies and matching plasma cutting consumables.
Key Product Highlights
Rated current: 45A
Duty cycle: 60%
Air-cooled handheld torch design
Non-high-frequency arc starting
Process gas: Air / N₂
Gas pressure: 4.5–5.0 bar
Gas flow: 120–130 L/min
Recommended post-flow: 55 seconds
Standard torch cable: 4 m
Replaceable cutting consumables
Bulk purchasing and OEM inquiries supported
Request a Quote for INWELT PT45 Plasma Cutting Torches
The PT45 is a manual air-cooled plasma cutting torch intended for use with a compatible non-HF plasma cutting power source.
The torch operates as part of a complete plasma cutting system that includes the power supply, process-gas supply, electrical connection, work return, and compatible cutting consumables.
During operation, the plasma system produces a concentrated high-temperature plasma arc that melts electrically conductive metal. The flowing gas helps remove molten material from the cutting kerf.
The PT45 has a rated current of 45A and is intended for compatible handheld cutting applications.
The basic cutting process involves:
The operator activates the torch through its control system.
Process gas flows through the torch head.
The compatible non-HF starting system initiates the plasma arc.
The concentrated plasma jet melts the workpiece material.
High-velocity gas removes molten metal from the cut.
After cutting, the system continues gas flow for a recommended cooling period.
The exact starting sequence depends on the plasma power source and torch configuration.
Non-HF means that the torch is designed for an arc-starting system that does not depend on a conventional high-frequency starting circuit.
Non-HF and high-frequency plasma cutting systems use different ignition arrangements.
Important: Non-HF is not a complete compatibility specification. Buyers must also confirm the power source's starting mechanism, control wiring, rear connector, and consumable configuration.
The PT45 should not be assumed to be compatible with every plasma cutter labeled CUT40, CUT45, or CUT50.
Specification | INWELT PT45 |
|---|---|
Brand | INWELT |
Product Name | PT45 Air-Cooled Plasma Cutting Torch |
Model Number | PT45 |
Product Type | Manual / Handheld Plasma Cutting Torch |
Rated Current | 45A |
Duty Cycle | 60% |
Cooling Type | Air-Cooled |
Process Gas | Air / Nitrogen (N₂) |
Gas Pressure | 4.5–5.0 bar |
Gas Flow | 120–130 L/min |
Arc Starting | Non-HF (Without High Frequency) |
Recommended Post-Flow | 55 seconds |
Standard Cable Length | 4 m |
Cutting Application | Electrically Conductive Metals |
Torch Consumables | Configuration-Matched Cutting Tips, Electrodes, Gas Diffusers and Protective Components |
Connection | Must Be Confirmed for the Selected Plasma Power Source |
Supply Type | Wholesale / OEM Inquiry |
Company | Changzhou Inwelt Welding Technology Co., Ltd. |
Note: The 55-second post-flow is a recommended cooling setting, not a claim that the torch itself contains a programmable timer. The plasma power source must support an appropriate post-flow function.
Actual cutting capacity, cable connector and consumable part numbers depend on the complete approved system configuration.
The PT45 is rated for 45A operation with a compatible plasma cutting power supply.
The rated current identifies the torch's intended electrical operating class.
Cutting thickness and cutting speed depend on the complete system, not on the torch current rating alone.
The PT45 uses an air-cooled configuration, eliminating the need for a separate water-cooling circuit.
This provides a practical torch arrangement for compatible portable and workshop plasma cutting equipment.
Proper process-gas flow and post-flow are essential for cooling the torch components.
The PT45 is designed for a compatible non-high-frequency plasma starting system.
For equipment manufacturers and replacement torch buyers, the non-HF specification is an important compatibility checkpoint.
The specific starting mechanism must still be verified before installation.
The PT45 specification lists Air / N₂ as the process gas.
Compressed air is commonly used for plasma cutting of electrically conductive metals.
Nitrogen may be used when the complete plasma cutting system and operating procedure support it.
For reliable cutting performance, use the specified gas pressure, flow and quality.
The PT45 torch has a specified duty cycle of 60%.
Duty cycle indicates a thermal operating limitation under the applicable rating conditions.
The complete plasma cutting system must operate within both the torch rating and the power source rating.
The actual duty-cycle test conditions should be confirmed from the relevant technical documentation.
After the cutting arc stops, process gas can continue flowing to remove residual heat from the torch head and consumables.
For the INWELT PT45 configuration, the recommended post-flow time is 55 seconds.
Proper post-flow helps support the cooling of the torch and its replaceable components.
The required setting must be implemented through a compatible power source or control system.
The standard PT45 cable length is 4 m.
This provides a practical working reach for handheld cutting applications in fabrication, maintenance and repair environments.
Buyers should confirm cable length, rear connector and control-wire configuration when ordering.
The PT45 torch uses replaceable front-end cutting components.
Depending on the approved configuration, these may include the electrode, cutting tip, gas diffuser, shield or retaining components.
Correct consumable selection helps maintain safe operation and cutting performance.
The PT45 can be used with a compatible plasma cutting system to cut electrically conductive metals.
Mild steel is a common material used in plasma cutting applications.
Typical uses include:
General metal fabrication
Steel plate preparation
Equipment repair
Brackets and structural components
Workshop maintenance
Cutting results depend on the material thickness, power source, process gas, consumables and operator technique.
The PT45 may be used for cutting stainless steel when supported by the complete plasma cutting system.
Applications include stainless steel sheet, fabricated components and maintenance work.
Cut-edge appearance, heat-affected zones and dross formation depend on cutting parameters and material conditions.
Aluminum is electrically conductive and can be cut using a compatible plasma cutting system.
The cutting setup must be suitable for aluminum, including the selected current, process gas and consumables.
Aluminum cutting performance should be verified for the actual machine and application.
The PT45 is suitable for consideration in professional workshops performing manual cutting operations, including:
Metalworking and fabrication
Industrial equipment maintenance
Machinery repair
General workshop cutting
Fabricated metal component preparation
The maximum cutting thickness cannot be determined from the torch's 45A rating alone.
Actual cutting capacity depends on:
Plasma power source output
Material type
Material thickness
Cutting speed
Process-gas pressure and flow
Consumable type and condition
Torch-to-work distance
Power source and torch compatibility
A recommended or production cutting capacity normally refers to a thickness that can be cut at a specified speed and quality level.
A severance capacity refers to a maximum material thickness that can be separated, often at a much lower cutting speed and with reduced edge quality.
These two values should not be confused.
Whether a PT45 system can cut 12 mm mild steel depends on the actual plasma power source, operating parameters, consumables and required cutting speed.
A reliable 12 mm cutting capability should only be published when supported by testing of the specific PT45 system.
For B2B buyers, request a cutting performance chart when purchasing torches for a particular machine or application.
Selecting a replacement plasma torch requires more than matching the amperage.
A plasma torch can have the correct rated current but still be incompatible with the existing machine.
Verify that the plasma cutting machine supports a compatible 45A-class torch.
Check:
Output current
Arc-starting method
Torch electrical interface
Trigger and control circuit
Gas supply system
Post-flow control
The PT45 is a non-HF torch.
It should only be used with a power source that supports the required starting arrangement.
A non-HF label alone does not confirm compatibility.
Plasma torches may use different rear-connection configurations.
Examples of connection details that buyers may need to verify include:
Direct cable connection
Integrated gas/electrical connection
Separate gas/electrical connections
Central adapter connection
Trigger/control wire quantity
These are compatibility checkpoints, not a claim that every connector configuration is included with this PT45 product.
The control-wire arrangement must match the plasma cutting machine.
Different systems may use different trigger circuits, control connectors and safety arrangements.
The electrode, nozzle, diffuser, retaining cap and other front-end consumables must be compatible with the selected torch head.
PT45, PT60, PT80, PMX45 and other similarly named plasma torch systems should not be treated as automatically interchangeable.
For replacement torch compatibility confirmation, provide:
Plasma cutter brand and model
Existing torch model
Power source output current
Arc-starting method
Rear-connector photographs
Control-wire details
Current torch consumable photographs
Required cable length
This information helps reduce the risk of ordering an incompatible torch.
Regular consumable inspection is important for maintaining consistent cutting performance.
The cutting tip constricts and directs the plasma jet.
A worn, enlarged or damaged nozzle orifice may contribute to poor cut quality and unstable cutting performance.
Replace the nozzle when its condition no longer meets the equipment manufacturer's operating requirements.
The electrode forms part of the plasma arc circuit.
Electrode erosion is normal during operation, but excessive wear can affect arc reliability and consumable performance.
Electrode compatibility must be verified against the selected torch head and starting system.
Depending on the torch configuration, the gas diffuser or swirl component helps control gas distribution inside the torch head.
Incorrect or damaged components can affect the plasma gas flow.
Protective and retaining components help hold the front-end consumables in the required configuration.
These parts should be installed and inspected according to the torch manufacturer's instructions.
Replacement requirements may also include:
Torch head
Trigger assembly
Torch handle
Cable assembly
Gas connection
Rear connector
Seals and related components
INWELT can evaluate inquiries for matching replacement parts based on the selected PT45 configuration.
When choosing a replacement plasma torch, buyers should compare the complete model specification rather than selecting only by rated current.
Feature | PT40 | PT45 | PT60 |
|---|---|---|---|
Rated Current | 40A | 45A | 60A |
Cooling | Air-Cooled | Air-Cooled | Air-Cooled |
Arc Starting | Non-HF | Non-HF | Non-HF / Pilot-Arc Configuration |
Duty Cycle | 60% | 60% | 60% |
Process Gas | Air / N₂ | Air / N₂ | Air / N₂ |
Typical Gas Pressure | 4.5–5.0 bar | 4.5–5.0 bar | 4.5–5.0 bar |
Gas Flow | 120–130 L/min | 120–130 L/min | 120–130 L/min |
Recommended Post-Flow | 35 sec | 55 sec | 55 sec |
Standard Cable | 4 m | 4 m | 6 m |
Specifications apply to the referenced INWELT configurations and should not be used to infer interchangeability between models.
The PT45 has a 45A current rating compared with the PT40's 40A rating.
For the referenced configurations, both use air cooling and non-HF starting, but their recommended post-flow times differ.
These differences do not automatically establish compatibility with the same power source or consumables.
The PT60 has a higher rated current and is available for compatible pilot-arc systems.
The PT45 is a 45A-class torch with a standard 4 m cable.
Choose according to the power source specification, arc-starting arrangement, required current, rear connector and consumable compatibility.
Correct maintenance can help reduce avoidable cutting problems and unnecessary consumable replacement.
Before servicing the torch, disconnect the equipment from its power source and follow the manufacturer's safety procedures.
Allow hot components to cool.
Check for:
Enlarged or irregular nozzle orifice
Excessive slag or debris
Heat damage
Cracks or deformation
Incorrect consumable installation
Check electrode condition and replace excessively worn or damaged components according to the equipment manufacturer's guidelines.
Confirm that the gas supply meets the required pressure and flow specifications.
For the PT45, the stated operating range is 4.5–5.0 bar and 120–130 L/min.
Use clean, dry gas suitable for the power source and cutting process.
Inspect the cable assembly, rear connector and trigger control components for visible damage.
Do not operate a torch with damaged electrical insulation, loose connections or defective control components.
Where supported by the power source, use the recommended 55-second post-flow setting.
Do not interrupt cooling gas flow prematurely.
Problem | Possible Causes | Recommended Checks |
|---|---|---|
Torch Does Not Start | Incompatible Starting System, Control-Wire Fault, Power Source Problem | Verify Non-HF Compatibility and Control Wiring |
Unstable Plasma Arc | Incorrect Gas Flow, Worn Consumables, Electrical Issues | Inspect Gas Supply, Electrode and Nozzle |
Poor Cut Quality | Worn Tip, Incorrect Travel Speed, Gas Problems | Inspect Consumables and Cutting Parameters |
Excessive Dross | Cutting Speed, Gas Flow, Material Condition | Review Cutting Technique and Settings |
Torch Overheating | Excessive Operating Load, Insufficient Cooling | Check Duty Cycle and Post-Flow |
Short Consumable Life | Incorrect Current, Poor Gas Quality, Incorrect Assembly | Verify Operating Conditions and Consumable Fit |
Replacement Torch Does Not Fit | Incorrect Rear Connector or Control Configuration | Compare Torch and Power Source Interfaces |
These are general troubleshooting considerations. The exact fault diagnosis must follow the plasma power source and torch manufacturer's instructions.
Changzhou Inwelt Welding Technology Co., Ltd. supplies welding and cutting torches, consumables and related accessories for professional B2B customers.
INWELT welcomes inquiries for PT45 plasma cutting torches from:
Plasma cutting equipment distributors
Welding equipment importers
Industrial welding and cutting wholesalers
Plasma cutter manufacturers
Equipment maintenance suppliers
OEM and private-label brands
Industrial fabrication companies
Large industrial buyers
Buyers can request quotations based on the required quantity, cable length, connection configuration and destination country.
For repeat orders, confirming a reference sample or drawing is recommended.
INWELT can evaluate project requirements involving:
Torch assembly specifications
Cable and connector configuration
Product labeling
Customer-brand packaging
Carton identification
Matching consumable packages
Product documentation requirements
Customization feasibility, minimum order quantities and final specifications should be confirmed for each project.
Customers may inquire about complete torch assemblies together with compatible replacement consumables.
Product matching should be based on the approved torch configuration and part specifications.
Industrial purchasing projects may require:
Technical drawings
Product specification sheets
Consumable identification
Electrical connection information
Dimensional inspection records
Applicable quality or conformity documents
Document availability and certification requirements should be confirmed for the actual product and production batch.
The INWELT PT45 is a 45A air-cooled handheld plasma cutting torch designed for compatible non-HF plasma cutting systems. Its standard cable length is 4 m.
The PT45 has a rated current of 45A and a specified duty cycle of 60%. The complete cutting system must operate within the ratings of both the torch and the power source.
The PT45 is specified for non-high-frequency (Non-HF) starting. The exact starting mechanism and power source compatibility must be confirmed before installation.
The PT45 specification lists compressed air or nitrogen (N₂). The selected gas must be supported by the complete plasma cutting system and operating procedure.
The specified operating gas pressure is 4.5–5.0 bar. The correct pressure setting should follow the approved torch and power source configuration.
The stated gas flow is 120–130 L/min. Insufficient or incorrect gas flow may affect cutting performance and torch cooling.
The recommended post-flow time is 55 seconds. This is a cooling recommendation, and the plasma power source must support the appropriate post-flow setting.
The standard PT45 cable length is 4 meters. Rear-connector and control-wire compatibility must be confirmed when ordering.
When connected to a compatible plasma cutting system, the PT45 can be used for electrically conductive metals, including mild steel, stainless steel and aluminum.
Cutting thickness depends on the plasma power source, workpiece material, cutting speed, gas supply and consumables. A guaranteed cutting thickness should be based on testing of the complete system.
No. Matching current ratings do not guarantee compatibility. Buyers must confirm the arc-starting method, rear connector, control wiring, gas connections and consumables.
The PT45 uses configuration-matched plasma cutting consumables, which may include electrodes, cutting tips, gas diffusers and protective components. Exact part numbers must be verified for the selected torch assembly.
Not automatically. These models may differ in rated current, starting system, connector configuration and consumables. Check the full technical specification before replacing a torch.
Yes. INWELT welcomes wholesale and OEM inquiries from distributors, equipment suppliers and industrial customers. Final product configuration, quantity and packaging requirements are confirmed during quotation.
Looking for a reliable supplier of PT45 45A Non-HF Plasma Cutting Torches for industrial distribution or equipment manufacturing?
INWELT welcomes professional inquiries for complete torch assemblies, matching consumables and OEM supply projects.
Please include the following details when requesting a quotation:
Torch Model: PT45
Rated Current: 45A
Required Cable Length: Standard 4 m or requested specification
Plasma Cutter Model: Brand and model number
Arc-Starting System: Required non-HF configuration
Rear Connector: Photographs or connection specification
Control Wiring: Required configuration
Order Quantity: Number of complete torch assemblies
Destination Country: For quotation and shipping arrangements
Packaging Requirements: Standard or OEM packaging
Contact INWELT for PT45 plasma torch specifications, wholesale quotations and OEM supply inquiries.
Company: Changzhou Inwelt Welding Technology Co., Ltd.
Website: https://www.czinwelt.com/
INWELT – Your Partner for Professional Welding and Plasma Cutting Torch Solutions.